Redul B200 PLC

Redul B200 is one of the most powerful compact programmable logic controllers on the market.

The controller modules are available for purchase from our web store.

SKU: B200 XX XXX Category:
Overview

APPLICATIONS

  • Remote I/O in oil and gas
  • Telemetry systems
  • Gas odorizing, gas heating systems
  • Utilities
  • Plastic manufacturing
  • Other small- and medium-sized systems and as remote I/Os for Redul B500/B600

FEATURES

  • Hot-swapping of all controller modules
  • Modular configuration, allowing flexible extension and change of configuration
  • Up to 70 modules in one rack
  • Interoperability with other REDUL PLCs on the shared bus or added bus segment
  • Extended temperature range
  • Programming with five IEC 61131-3 languages + CFC, in Sigma LD software

DESIGN

  • Compact dimensions, 15 x 101 x 104 mm (W×H×D)
  • Convenient chassis—replace modules without disconnecting cables
  • Passive cooling; no mechanical or rotating components
  • Installation on a 35-mm DIN rail
  • Possibility of using locking and sealing elements for fiscal applications
  • Location coding according to the module type

 

Specifications
Processor typeARM Cortex-Aхх
RAM512 Mb
Flash1 Gb
Minimum cycle time1 ms
Scan time1 ms
Timing accuracy50 µs
Input power18…36 VDC
I/O module dimensions (W x H x D)12.9 х 101 х 109 mm
Operating temperature-40...+60 °С
ApprovalsCE, EAC, FCC-ready
Communications

Supported interfaces

  • RS-232 (9-pin, full duplex, speed 300–115, 200 bps, opto-isolation 500/1500 V, overvoltage protection)
  • RS-422/RS-485 (9-pin, speed 300–115, 200 bps, full-channel opto-isolation 500/1500 V, overvoltage protection): up to 96 ports per controller
  • Ethernet 10/100/1000 RJ-45 (full duplex): up to 2 ports per CPU
  • Ethernet 10/100/1000 FO (single-mode, multi-mode): up to 1 port per CPU

Built-in communication protocols*

  • IEC 60870-5-101 (master/slave)
  • IEC 60870-5-104 (master/slave)
  • Modbus RTU (master/slave, with expansion capabilities)
  • Modbus TCP (master/slave, with expansion capabilities)
  • OPC DA
  • OPC UA
Rack Connections

Redul B200 mixed connection, B500 CPU rack + B200 I/O racks

Redul B200 – Ring

Redul B200 – Star

Modules
ModuleDescriptionChannels (ports)
BASE MODULES
CU00021Central processor unit module
• Support of redundant operation
• ARM Cortex-Axx
• 512 MB RAM, 1 × 1 GB SSD
• 1 × RS-232, 1 × RS-485
• 2 × Ethernet RJ-45

CU00021 (W) additionally includes web server with support of Web visualization
CU00031Central processor unit module
• Support of redundant operation
• ARM Cortex-Axx
• 512 MB RAM, 1 × 1 GB SSD
• 1 × RS-232, 1 × RS-485
• 2 × Ethernet SFP

CU00031 (W) additionally includes web server with support of Web visualization
CU00051
Central processor unit module
• Support of redundant operation
• Intel Atom
• 2 GB RAM, 1 × 4 GB SSD
• 1 × RS-232, 1 × RS-485
• 4 × Ethernet RJ-45
• 2 × USB host
• GPS receiver

CU00051 (W) additionally includes web server with support of Web visualization
-
CU00061
Central processor unit module
• Support of redundant operation
• Intel Atom
• 2 GB RAM, 1 × 4 GB SSD
• 1 × RS-232, 1 × RS-485
• 2 × Ethernet RJ-45, 2 × Ethernet SFP
• 2 × USB host
• GPS receiver

CU00061 (W) additionally includes web server with support of Web visualization
-
CU00071
Central processor unit module
• Support of redundant operation
• Intel Atom
• 2 GB RAM, 1 × 4 GB SSD
• 1 × RS-232, 1 × RS-485,
• 2 × Ethernet RJ-45, 2 × Ethernet SFP
• 2 × USB host, 1 × DVI
• GPS receiver

CU00071 (W) additionally includes web server with support of Web visualization
-
PP00011
24 VDC, 75 W power supply module, without galvanic isolation-
PP0002124 VDC, 75 W power supply module, with galvanic isolation-
PP00031220 VAC/VDC, 75 W power supply module, with galvanic isolation-
COMMUNICATION MODULES
CP04011Communication processor RS-485 (Modbus RTU), 4 ports4
CP02021Communication processor Ethernet (Modbus TCP), 2 ports2
CP06111Communication processor for Redul bus segments, EtherCAT, RJ-45, 6 ports6
ANALOG MODULES
AI16011
Analog input, AI module (current)
• Current measuring range: 0…20 mA, 4…20 mA
• 16 channels
• Resolution: 14 bits (including overflow)
• Operating error under normal conditions: ±0.1%
• Shared ADC for all channels
• Common galvanic isolation
16
AI16081
Analog input, AI module (current, HART)
• Current measuring range: 4…20 mA
• 16 channels
• Resolution: 16 bits (including overflow)
• Operating error under normal conditions: ± 0.1%
• Built-in HART protocol
• 1 ADC and 1 HART-modem per channel group (2 groups of 8 channels)
• Group galvanic isolation
16
AI08021Analog input, AI module (current, HART)
• Current measuring range: 0…20 mA, 4…20 mA
• 8 channels
• Operating error under normal conditions: ± 0.1%
• Built-in HART protocol and HART modem
• Channel galvanic isolation
AI08031
Analog input, AI module (thermal resistances, thermocouples)
• Thermal resistance measurement range: 20…400 Ohm
• 8 channels
• Supported thermal resistances: Cu50, Cu100, Pt50, Pt100, Ni50, Ni100
• Supported thermocouples: R, S, B, J, T, E, K, N, A-1, A-2, A-3, L, M
• Resolution: 24 bits (including overflow)
• Operating error under normal conditions: ±0.1%
• Common galvanic isolation
8
AI08041
Analog input, AI module (current, voltage; high-accuracy)
• Current measuring range: 0…20 mA, 4…20 mA
• Voltage measuring range: 0…+10 V, -10…+10 V
• 8 channels
• Resolution: 16 bits (including overflow)
• Operating error under normal conditions: ±0.025%
• Channel galvanic isolation
• Individual ADC for each channel
8
AI08051Analog input, AI module (current, voltage)
• Current measuring range: 0…20 mA, 4…20 mA
• Voltage measuring range: 0…+10 V, -10…+10 V
• 8 channels
• Resolution: 14 bits (including overflow)
• Operating error under normal conditions: ±0.1%
• Channel galvanic isolation
• Shared ADC for all channels
8
AO08011
Analog output module (current)
• Output range, current: 0…20 mA, 4…20 mA
• 8 channels
• Resolution: 16 bits
• Operating error under normal conditions: ±0.1%
• Channel galvanic isolation
8
AO08021Analog output module (current, HART)
• Output range, current: 0…20 mA, 4…20 mA (HART)
• 8 channels
• Resolution: 16 bits
• Built-in HART protocol and HART modem
• Operating error under normal conditions: ±0.1%
• Channel galvanic isolation
AO08031
Analog output module (current, voltage)
• Output range, current: 0...20 mA, 4…20 mA
• Output range, voltage: 0…+10 V, -10…+10 V
• 8 channels
• Resolution: 16 bits
• Operating error under normal conditions: ±0.1%
• Channel galvanic isolation
8
AS08011Hybrid analog module (current, voltage)
• Current measuring range / output current: 0…20 mA, 4…20 mA
• Voltage measuring range / output voltage: 0…+10 V, -10…+10 V
• 6 × AI channels, shared ADC for all channels
• 2 × AO channels, individual ADC for each channel
• Resolution: 14 bits (including overflow)
• Operating error under normal conditions: ±0.1%
• Channel galvanic isolation
DIGITAL MODULES
DI32011Digital input, DI module
• Input current: 24 VDC
• 32 channels (4 groups by 8 channels)
• Group galvanic isolation
32
DI32111Digital input, DI module
• Input current: 24 VDC
• 32 channels (4 groups by 8 channels)
• Galvanic isolation with bus and power supply – 1,500 V
• Group galvanic isolation
32
DI16021Digital input, DI module
• Input current: 220 VAC/VDC
• 16 channels
• Channel galvanic isolation
16
DO32011Digital output, DO module
• Output current: 24 VDC / 0.5 A
• 32 channels (4 groups by 8 channels)
• Group galvanic isolation
32
DO16021Digital output, DO module
• Output current: 220 VAC / 2 А, 220 VDC / 0.3 A
• 16 channels
• Channel galvanic isolation
32
DS32011
Hybrid digital module
• 24 × DI (3 groups by 8 channels), 24 VDC
• 8 × DO, 24 VDC/0.5 A
• Group galvanic isolation
24 (input) / 8 (output)
COUNTER MODULES
DA03011Counter/digital module
• Channel supply voltage: 4…24 V
• Frequency measurement ranges: 1…10 kHz (enhanced accuracy), 1…500 kHz
• Pulse measurement range: from 1…264 (with overflow)
• Operating error under normal conditions, frequency: less than ± 0.01%
• Pulse-counting error: ±1 pulse
• 3 × counter channels
• 6 × DI channels, 24 V
• 6 × DO channels, 24 V / 0.5 A
• Channel galvanic isolation of the counter channels
3/6/6
DA03021Counter/digital module
• Channel supply voltage: 5, 12, 24 V
• Frequency measurement range: 1 Hz…500 kHz
• Pulse measurement range: 1…264 (with overflow)
• Operating error under normal conditions, frequency: less than ± 0.01%
• Pulse-counting error: ±1 pulse
• 3 × counter channels
• 1 × generator channel
• 6 × DI channels, 24 V
• 6 × DO channels, 24 V / 0.5 A
• Channel galvanic isolation of the counter channels
• Electronic overspeed trip software
3/1/6/6
BUS MODULES
ST00001Termination module without bus extension function-
ST01011Bus extension module (IN), RJ-45, non-redundant bus1
ST01021Bus extension module (OUT), RJ-45, non-redundant bus1
ST02011Bus extension module (IN), RJ-45, redundant bus2
ST02021Bus extension module (OUT), RJ-45, redundant bus2
ST02111Bus extension module (IN), SFP, redundant bus2
ST02121Bus extension module (OUT), SFP, redundant bus2
Downloads

Certificates
EC Declaration of Conformity

Manuals

To download complete manuals for Redul B200 controllers, please, send an e-mail to support@gp-systems.com

Dimensions

Input / output and communication processor modules

 

Interface Module

 

CPU Module